| Source |
Cobalt - 60 Gamma ray |
| Application |
Radiography of Material thickness ranging over (steel) 60mm
- 200mm |
| Source |
Iridium - 192 Gamma ray |
| Application |
Radiography of material thickness (steel) up to 60mm |
| Source |
X- ray (100 - 250 kv) |
| Application |
Radiography of Material thickness ranging from (steel)
2.5mm - 40mm |
|
|
| Application |
Testing of internal flaws in welding, raw-materials
& castings |
| Test range |
5mm - 5000mm of steel (Longitudinal wave) |
| Mode |
Pulse echo / contact / manual |
MAGNETIC PARTICLE
TEST (MT)
|
| Application |
Testing to detect flaws on surface and
sub - surface / open to surface |
| Type |
Only solvent method |
LIQUID PENETRANT TEST (PT)
|
| Application |
Testing to detect flaws on surface / open to surface |
| Type |
Only solvent method |
| |
| Application |
To check the accurate thickness of the
materials |
| Accuracy |
+ or - 0.1 mm |
| |
| Application |
To relieve the stress on the welded components. |
| Method |
Electrical resistance using coils |